New Cooling Tower / Cooling Tower Main Equipment / Agitator / Mixers / Positive Displacement Pump / Strainer / Air Cooled Heat Exchanger ( Fin Fan )
 
 

COOLING TOWER

INNOVEK was Cooling Technology Institute (CTI) corporate member then all our cooling tower designs comply to CTI standard with latest design program software support. INNOVEK‘s cooling tower supplied cover all range of cooling tower in market as following type :
     • Counter Flow & Cross Flow Cooling tower
     • Concrete ,HDG ,FRP pultrusion and wood structure
     • Cooling tower package
     • Close circuit cooling tower.
INNOVEK services cover in design, engineering, procurement and construction of new cooling. Beside that INNOVEK also offer “Turnkey” cooling tower package including chemical treatment skid, pumps, lighting system, Lightning system, instrumentation, civil work and piping work in customer battery limit.

     1 Counter flow concrete structure
     2 Cross flow wood structure
     3 Cross flow FRP structure

COOLING TOWER MAIN EQUIPMENT

Brentwood ( U.S.A. )-Fill pack
     • High – Performance splash Fills
     • Anti – Fouling Film Fills
     • High – Performance Film Fills
     • Edge Bonding
     • Herring bond fill Integrate fill drift and louver

     1 Cross Flute
     2 Vertical Offset
     3 Vertical Flute  
     4 Herring bone

Brentwood ( U.S.A. )-Drift Eliminator
     • Counter flow cellular drift eliminators
     • Counter flow blade drift eliminators

     1 Cellular Type
     2 Blade type

COFIMCO Fan ( ITALY )
     • COFIMCO AV Series
     • COFIMCO M-Series
     • COFIMCO 60F-Series
     • COFIMCO H-series
     • COFIMCO B-Series
     • COFIMCO CX-Series
     • COFIMCO Z-Series
     • FRP Pultrusion fan avialable for all model
     • Aluminim Extrusion available for all model
     • Rigid fan shaft and Flexy fan shaft available

     1 FRP Pultruded Fan
     2 M Series Aluminum fan
     3 CX- Superlow noise series   
     4 Flexi Fan Series
     5 AV Fan Series    
     6 FRP Pultruded G Series

Hudson Product Corp. (U.S.A)
      Hudson Tuf- Lite ® /Tuf-Lite II ® /Tuflite III ® fan assemblies and related fan parts which include fan blades, hub assemblies, seal disc,         bushings and related hardware.
      Hudson Fin Fan ® bearings.
      Tip seal honeycomb material.
      Inlet bell sets

     1 TUFLITE II ® old color
     2 TUFLITE ® Blade
     3 TUFLITE II ® new color

Amarillo Products ( U.S.A. )
     • Right angle gear for cooling tower
     • Composite Drive Shaft For Cooling Tower
     • A-Series compatible for Marely gear
     • Right Angle pump

     1 Composite Drive Shaft
     2 Double Reduction Gear
     3 Parallel Shaft Gear Drives

HANSAN GEAR ( BELGIUM)

ADDAX COMPOSITE DRIVE SHAFT

BRENT WOOD /MIDWEST SPRAY NOZZLE FOR COOLING TOWER

FRP FAN STACK
Our state of art fan stack design to suitable your cooling tower fan size and easy for installation. View port, FRP shaft guard, Access door and fire retardant are optional depend your requirement. We also made to order fan stack incase your stack damage in few section.

     1 FRP FAN STACK WITH FIRED RETARDANCE
     2 FRP Stack one segment
     3 Fan stack join assemblies
MURPHY VIBRATION SWITCH
AGITATORS / MIXERS
LIGHTNIN / PLENTY MIXERS (U.S.A/ UK)
     • Portable and Fixed Mount Mixers
     • Side Entry Mixers
     • Top Entry Mixers
     • Static / Inline Mixer
     1 Plenty side entry mixers
     2 Static Mixer
     3 Lightnin Series 98   
     4 Lightinin Series 700-800
     
Plenty Mirrlees Pumps / UK
     • Rotary Vane Pump
     • Triro Three Screw Pump
     • Twinro Two Screw Pump
     • Maxmo Sugar Pump
VACUUM PUMP/ BLOWERS
ROTARY BLOWER & VACUUM PUMP TYPE ARJ
The rotary blower is three lobe Roots type blower featuring high performance, low noise and less vibration. Special gas blowers with mechanical seal or non-contact seal and high design pressure are available.
VERTICAL DRY VACUUMPUMP TYPE TRV.
The dry vacuum pump is multi-stage Roots type. It is constructed as a four stage vertical type. The vacuum pump can be operated completely dry condition from the ultimate pressure up to atmospheric pressure. Top down transportation of gas ensures rapid and complete draining.
DRY VACUUM PUMP TYPE TRM
The dry vacuum pump is multi-stage Roots type. It is constructed as a three stage horizontal type with intermediate heat exchanger. The vacuum pump can be operated completely dry condition from the ultimate pressure up to atmospheric pressure. The intermediate heat exchanger insures easy solvent recovery. The all pump equipments are equipped together on a common frame
WATERING VACUUM PUMP TYPE SRH
The water ring vacuum pump type SRH is a high performance, low noise vacuum pump, supported by our superior manufacturing technology. The adoption of a very simple operating system of single-rotation and single-compression type offers advantages of wide application
AIR COOLED HEAT EXCHANGER (FINFAN)
 
INDUCE DRAFT CONFIGURATION  
FORCE DRAFT CONFIGULATION  
UPGRADE TUBE BUNDLE MATERIAL
to exotic Material ie. Duplex, SS316, incoloy etc.
HUDSON/COFIMCO FAN
High efficiency aluminum and FRP fan
 
HUDSON FIN FAN BEARING
Special design for fin fan application
     • 2 times longer life
     • Self alignment
     • Water channel cast-in to prevent water accumulation
     • Easy installation without modification
     • Equivalent to Dodge SCM4 and type E
 
FIN FAN BELT
High quality belt for fin fan application with Anti-static type
 
TIMMING PULLEY
Lower slippage and lighter weight design
 
INLET BELL
Use for adjust inlet air flow profile to reduce hot air re-circulation can increase more air flow 3-5%
TIP SEAL
Use for adjust tip clearance to stop air leak and increase air flow 3-5%
HEADER PLUG AND GASKET
Available all material and size up on your requirement
 